Refine Your Search

Topic

Search Results

Standard

Transmission Oil Cooler Hose

2014-06-04
HISTORICAL
J1532_201406
This SAE Standard covers hose intended for use with automatic transmission cooling system applications. Type A hoses are intended for original equipment or replacement applications while Type B hoses are intended for aftermarket auxiliary cooler applications only. The reference fluid for tests requiring the use of automatic transmission fluid (ATF) shall be Dexron III / Mercon 5 or equivalent ATF that is agreed to by hose manufacturer and customer.
Standard

Recommended Practices for Design and Evaluation of Passenger and Light Truck Coolant Hose Clamped Joints

2013-07-09
CURRENT
J1697_201307
This SAE Recommended Practice covers recommended practices for design and evaluation of hose clamped joints primarily in automotive applications. It is intended to: (a) evaluate current joint designs, (b) compare existing designs, (c) aid in the development of new designs, (d) give objective results once weights are set, (e) rate the overall design and individual sections of design, and (f) encourage future research by industry and the OEM's.
Standard

Test Method for Evaluating the Sealing Capability of Hose Connections with a PVT Test Facility

2012-10-24
CURRENT
J1610_201210
This test method provides a standardized procedure for evaluating the sealing capability of a hose connection or any of the individual components of the connection with a pressure, vibration, and temperature (PVT) test facility. This test method consists of a test procedure which includes vibration and coolant flow (#1 ) and a similar test procedure specified without vibration or coolant flow (#2). Any test parameters, other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requestor.
Standard

Fuel and Oil Hoses

2012-02-17
HISTORICAL
J30_201202
This SAE standard covers fuel, oil, or emission hose for use in coupled and uncoupled applications, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapors present in either the fuel system or in the crankcase of internal combustion engines in mobile or stationary applications. This standard covers the hose portion only. If assembly / coupling is required, that is to be agreed to between the customer and assembler, along with the specific requirements.
Standard

Dimensions and Tolerances for Coolant System Hoses

2010-08-26
HISTORICAL
J2387_201008
The purpose of this SAE Recommended Practice is to provide dimensions for both standard and thin-wall hoses and to provide commercial and precision tolerances for SAE 20R3 and SAE 20R4 coolant system hoses.
Standard

Hose Gauge Evaluation Procedure

2010-06-16
HISTORICAL
J2666_201006
The Gauge Evaluation Procedure Task Force was formed by the Non-Hydraulic Hose Committee to develop a gauge evaluation procedure to be used when evaluating the capability of gauges used for hose measurement. The use of a standard method for gauge evaluation will help users easily compare equipment capability. The information provided in this recommendation is based on the methods used to produce the data presented in SAE J1759 and J2605.
Standard

Test Method for Evaluating the Electrical Resistance of Coolant System Hose Covers

2010-02-15
HISTORICAL
J2790_201002
This test method provides a standardized procedure for evaluating the electrical resistance of automotive coolant hose covers. It is known that an electrical potential exists between the engine and the radiator. Coolant hose cover conductivity has been determined to be a factor to reduce hose clamp life when vehicle build variations allow possible contact of the hose or the clamp to metal components on the radiator and engine thus completing an electrical circuit. The ensuing electrical current can undercut the clamp protective coating, leaving it vulnerable to the corrosive effects of road salts, moisture, and other environmental contaminants. SAE Recommended Practice J1684 addresses the electrochemical resistance of the tube portion of the coolant hose.
Standard

Coolant Hose—Normal Service Type Convoluted, Wire Support Hose (Supplement to SAE J20 for Government Use Replacing Part of MS51008)

2009-06-04
HISTORICAL
J20/2_200906
This SAE Standard provides ordering information for any SAE 20R5 hose type (such as “EC, HT, LT” or combination thereof.) This is a wire-reinforced hose for coolant circulating systems of automotive type engines. This hose consists of a convoluted section with plain ends. The hose shall contain a wire helix or helices in the convoluted section. It is a supplement for Government use but may be used by others.
Standard

Hose Clamp Specifications

2009-03-06
HISTORICAL
J1508_200903
This SAE Standard covers thirty-two (32) types of clamps most commonly and suitably being used on OEM coolant, fuel, oil, vacuum, and emission systems.
Standard

Geometric Dimensions and Tolerancing for Curved Hose

2009-03-05
HISTORICAL
J2370_200903
To provide the curved hose industry and their customers with a recommended practice for applying GD&T procedures to curved hoses and to provide generic curved hose drawings that represent the application of GD&T to typical curved hose parts. Dimensioning and Tolerancing will be in accordance with ASME Y14.5M.
Standard

Fuel and Oil Hoses

2008-12-23
HISTORICAL
J30_200812
This SAE standard covers fuel, oil, or emission hose for use in coupled and uncoupled applications, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapors present in either the fuel system or in the crankcase of internal combustion engines in mobile or stationary applications. This standard covers the hose portion only. If assembly / coupling is required, that is to be agreed to between the customer and assembler, along with the specific requirements.
Standard

Type "F" Clamps for Plumbing Applications

2008-12-02
HISTORICAL
J1670_200812
This SAE Standard covers complete dimensional and general specifications for worm drive hose clamps for general use in the plumbing industry.
Standard

Test Method for Evaluating the Electrical Resistance of Coolant System Hose Covers

2007-06-15
HISTORICAL
J2790_200706
This test method provides a standardized procedure for evaluating the electrical resistance of automotive coolant hose covers. It is known that an electrical potential exists between the engine and the radiator. Coolant hose cover conductivity has been determined to be a factor to reduce hose clamp life when vehicle build variations allow possible contact of the hose or the clamp to metal components on the radiator and engine thus completing an electrical circuit. The ensuing electrical current can undercut the clamp protective coating, leaving it vulnerable to the corrosive effects of road salts, moisture, and other environmental contaminants. SAE Recommended Practice J1684 addresses the electrochemical resistance of the tube portion of the coolant hose.
Standard

Coolant System Hoses

2006-06-19
HISTORICAL
J20_200606
This SAE Standard covers reinforced and flexible hoses intended for use in water and ethylene glycol-based engine-coolant system applications.
Standard

Non-Contact Hose Measurement Study 1

2006-01-04
HISTORICAL
J2605_200601
The Hose Measurement Task Force conducted a round-robin study to determine the measuring capability of automotive suppliers and users to simultaneously measure the Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall), and Wall thickness Variation (WV) of hose using a laser-based, non-contact LOTIS QC-20 gauging device. Three (3) companies (all end users) participated in this testing with one of the three companies performing the GR&R calculations presented herein. Based upon the round-robin study this report will detail procedures, test measuring devices, results, and conclusions.
Standard

SAE Hose Measurement Study

2006-01-04
HISTORICAL
J1759_200601
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
Standard

Test Method for Evaluating the Electrochemical Resistance of Coolant System Hoses and Materials

2005-09-12
HISTORICAL
J1684_200509
This test method provides a standardized procedure for evaluating the electrochemical resistance of automotive coolant hose and materials. Electrochemical degradation has been determined to be a major cause of EPDM coolant system hose failures. The test method consists of a procedure which induces voltage to a test specimen while it is exposed to a water/coolant solution. Method #1, referred to as a “Brabolyzer” test, is a whole hose test. Method #2, referred to as a “U” tube test, uses cured plate samples or plates prepared from tube material removed from hose (Method No. 2 is intended as a screening test only). Any test parameters other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requester.
X